   EVACZ series column AC charging pile adopts pillar design which looks simple and elegant and with stable frame layout. It is with complete protecting functions such as protection for emergency stop, protection for over/under voltage, production for overcurrent, protection for PWM anomaly, protetion for connection anomaly and other protection mechanism.  Two plugs are designed independently without interference, it can be applied for residence community, industrial zone, highway service areas, parking lots, and other charging places.  It is an efficient DC charging device that provides power supply for new energy vehicles with on-board chargers.

EVACZ series column AC charging pile
Description EVACZ07AG-1  EVACZ07AG-2 
AC input voltage 176Vac~264Vac 176Vac~264Vac
AC input current ≤32A         ≤64A
AC power frequency 50±5Hz  50±5Hz
Input power factor >0.99     >0.99
Maximum output power ≤7kW         ≤14kW
AC output voltage 176Vac~264Vac 176Vac~264Vac
AC output current ≤32A         ≤64A
Stabilized current precision ±0.5%   ±0.5%
Output current error ≤±1%   ≤±1%
Output voltage error ±0.5%   ±0.5%
Full load conversion efficiency ≥99.9%  ≥99.9% 
 Charging mode Auto-full charge、 Time mode、 Amperage mode、 Amount mode、 Appointment mode
Display     4.3 inch highlight touch panel
Harmonic curren(THD)  ≤5%(50%-100% Output power) ≤10%(20% Output power) 
 Charging way Password to start、Plug and charge、Credit to start、 Scan QR code to start
Working Temperature -20℃~+50℃ 
Cooling mode Forced air cooling
Relative humidity permission 0~95%(non- condensation)
Maximum altitude permission 2000M 
 Noise level  ≤50dB 
PWM duty cycle  0.533
IP grade: IP54 
Stand-by power consumption  ≤20W 
MTBF MTBF≥8796h 
Size (mm) 1600*280*120 